Description

This can cause the valve spindle to seize. It often becomes stiff to turn at first and the valve may give intermittent problems. Eventually, the spindle may become so stiff that the valve motor cannot turn it at all.

That noise and that bump are diagnostic. They tell us that the valve has moved into the mid-position where both Heating and Hot Water ports are open. If you can make a Honeywell 3-port mid-position valve move into all three of those positions, the valve and controls appear to be wired correctly and the valve appears to be working normally. Typically, a small or medium sized property will have either one 3-port valve (which splits the central heating water flow between cylinder and radiators) or two 2-port valves (one governing flow to the cylinder and one governing flow to the radiators). Honeywell V4073A1039 22mm 3-port mid-position diverter valve. These are 5-wire valves. When used with other Honeywell controls the setup is know as Y Plan Honeywell V4073A1039 22mm 3-port mid-position motorised valve showing inlet port AB and outlet ports A and B. This valve can be open to either port A or port B, or to both ports at the same timeIf you know how to work safely with mains voltage electricity, the valve motor can be tested with a multimeter. With the mains electrical supply turned off and isolated, the resistance across the two motor wires (either both blue or both orange) can be tested. To test correctly, at least one of the two motor wires must be disconnected from the heating wiring circuit. When using two 2-port valves, the control system may be known as a Sundial S Plan system or a Honeywell S Plan system. The Honeywell motorised valve faults detailed above are likely to apply to most domestic Honeywell valves. In larger properties, 28mm valves may be used (the 5-wire 3-port V4073A1088 and the 6-wire 2-port V4043H1106). The 28mm V4043H1106 2-port zone valve has a6 th wire, coloured white. This white wire might not be used. In that case it should be made safe electrically.

There is, however, more information the lever can give us if we know what we’re looking for. The lever pushes the valve open against the return spring. The valve does not pull the lever over towards the open end as the valve opens. A failed motor will prevent the motorised valve from opening but it is not the only cause of a valve failing to open correctly. After years of use, the O rings sealing the valve spindle (or actuator shaft) can fail. When this happens, central heating water will seep past and will corrode the metals.When Heating is also called for, the white wire is energised and the valve will motor to, and stop in, a mid-position. Power for the boiler is still supplied directly from the cylinder thermostat. The orange valve wire may have a potential of 230V but this is coming from the cylinder stat (to which the orange wire is also connected) and not from the circuitry of the valve. The orange wired motors are less robust. I have had several jobs since where customers complained about regular replacement motors on s plan systems, so I replaced with blue wired and had longer stints between subsequent replacements. Basically you will get 5 years plus from a blue wired motor, but only between 2-5 years on an orange wired motor - anecdotal evidence only, so don't hold me to this, but it seems the honeywell guy was telling some truth in my experience. Inside a Honeywell V4073A 3-port motorised valve showing the rubber ball which closes one or other port, never both.

You should be able to feel a bit of spring resistance, right at the far end (Man Open end) of the slot. The Honeywell V4043H1106 28mm 2-port zone valve has 6 wires. Five of these wires are the same as 22mm 2-port valve.Green/yellow is Earth, blue is Neutral, brown is Live (or Line) to the motor, grey and orange are connected to the end switch and form part of a separate circuit.The commonest fault with Honeywell motorised valves is motor failure. Honeywell valve motor fault? Testing a Synchron valve motor The auxiliary circuit allows several 2-port motorised valves to be used to control separate zones without interacting electrically. Otherwise, if several zone valves were used without auxiliary circuits, and all were connected to the same pump so that the Live wire that opened each valve also fed the pump Live, there would be problems. Fortunately I do have a multimeter but didn't need it because my valves have an led that indicates when open. So I operated the valve manually and the led lit up and everything started up as normal. So I knew the motor was receiving power.. Honeywell say that the manual lever located on the end of the powerhead is not a position indicator and should be used used for filling the system and for draining down only.

With the powerhead cover removed you also have access to the screw which retains the motor. The motor can, if necessary, be removed without disconnecting the powerhead from the valve body. I had an issue recently of a valve not working. Turns out it was the motor so I replaced it with a motr from Screwfix.. The rubber ball sits against the circular port (right side in photo), closing it off. We’re told that the ball touches one edge of the circular port first, causing the ball to rotate slightly on its spindle. This regular slight rotation evens out distortions in the ball. A little piece of elegant design work by Honeywell!where can i buy the replacement motor from on the high street today and what's a reasonable price for it? In normal operation, with a heat-only boiler, central heating water is heated in the boiler and then pumped round the system by a circulating pump. Motorised valves are used to split or divert the flow. The heated water can either be sent to the radiators (or underfloor heating) or to the cylinder coil to heat the domestic hot tap water. The cooled circulating water is then returned to the boiler to be heated again. A Switchmaster Midi 3-port valve body with a seized spindle. This motorised valve was also rusting through round the screw in the picture Honeywell powerhead (actuator) jams? A normally-open valve is open when no power is being applied to it and needs electrical power to drive it closed. Honeywell Actuator Motor for V4043H, V4044C and V4073A Valves – Honeywell Syncron Motor.Only one replacement motor (40002737-003) is required for all modern motorised valves irrespective of body size, pipe connection type or whether 2 or 3 ports. Delivery Time